\documentclass[paper=A4]{article} \usepackage[utf8]{inputenc} \usepackage[a4paper, left=2cm, right=2cm, top=2cm, bottom=2cm]{geometry} \usepackage{siunitx} \sisetup{ group-separator = {.}, input-decimal-markers={.}, output-decimal-marker = {,}, group-minimum-digits=4} \usepackage{graphicx} \usepackage{fancyhdr} \usepackage{lastpage} \usepackage{subfigure} \usepackage{float} \usepackage{multicol} \usepackage{amsmath, amssymb} \pagestyle{fancy} \fancyhf{} \rhead{\includegraphics*[scale=0.03]{bilder/Fasttube-Logo.png}} \rfoot{Page \thepage \hspace{1pt} of \pageref{LastPage}} \begin{document} \lhead{Car 313, 06.03.2025, Rev. 1} \chead{\large Voltage Measurement Error Calculation} \hfill \break \hfill \break We use the C-ADC of the ADBMS6830B to measure the cell voltages of the battery. The maximum lifetime error for voltage measurement is $\pm \SI{2}{mV}$, since the maximum voltage of the cell is $\SI{4.2}{V}$. (Fig. \ref{fig:adbms}) \cite{datasheet} \begin{figure}[H] \centering \includegraphics[width=\textwidth]{./bilder/adbms.png} \caption{ADBMS6830B specifications} \label{fig:adbms} \end{figure} \bibliographystyle{plain} %\nocite{*} \renewcommand\refname{Reference} \begin{thebibliography}{00} \bibitem{datasheet} \textit{Data Sheet ADBMS6830B Rev.0 page 5}. analog.com, 01.2024. \end{thebibliography} \end{document}