diff --git a/voltage-measurement-error/AMS_V_error.pdf b/voltage-measurement-error/AMS_V_error.pdf deleted file mode 100644 index aa8bb1d..0000000 Binary files a/voltage-measurement-error/AMS_V_error.pdf and /dev/null differ diff --git a/voltage-measurement-error/AMS_V_error.tex b/voltage-measurement-error/AMS_V_error.tex deleted file mode 100644 index 1f7b54b..0000000 --- a/voltage-measurement-error/AMS_V_error.tex +++ /dev/null @@ -1,52 +0,0 @@ -\documentclass[paper=A4]{article} -\usepackage[utf8]{inputenc} - -\usepackage[a4paper, left=2cm, right=2cm, top=2cm, bottom=2cm]{geometry} - -\usepackage{siunitx} -\sisetup{ - group-separator = {.}, - input-decimal-markers={.}, - output-decimal-marker = {,}, - group-minimum-digits=4} -\usepackage{graphicx} -\usepackage{fancyhdr} -\usepackage{lastpage} -\usepackage{subfigure} -\usepackage{float} -\usepackage{multicol} -\usepackage{amsmath, amssymb} - -\pagestyle{fancy} -\fancyhf{} - -\rhead{\includegraphics*[scale=0.03]{bilder/Fasttube-Logo.png}} -\rfoot{Page \thepage \hspace{1pt} of \pageref{LastPage}} - -\begin{document} - -\lhead{Car 313, 06.03.2025, Rev. 1} -\chead{\large Voltage Measurement Error Calculation} - -\hfill \break -\hfill \break -We use the C-ADC of the ADBMS6830B to measure the cell voltages of the battery. The maximum lifetime error for voltage measurement is $\pm \SI{2}{mV}$, since the maximum voltage of the cell is $\SI{4.2}{V}$. (Fig. \ref{fig:adbms}) \cite{datasheet} - -\begin{figure}[H] - \centering - \includegraphics[width=\textwidth]{./bilder/adbms.png} - \caption{ADBMS6830B specifications} - \label{fig:adbms} -\end{figure} - -\bibliographystyle{plain} -%\nocite{*} - -\renewcommand\refname{Reference} -\begin{thebibliography}{00} - - \bibitem{datasheet} \textit{Data Sheet ADBMS6830B Rev.0 page 5}. analog.com, 01.2024. - -\end{thebibliography} - -\end{document} diff --git a/voltage-measurement-error/Pictures/FaSTTUBe_Logo_ohneAuto.png b/voltage-measurement-error/Pictures/FaSTTUBe_Logo_ohneAuto.png new file mode 100644 index 0000000..e402449 Binary files /dev/null and b/voltage-measurement-error/Pictures/FaSTTUBe_Logo_ohneAuto.png differ diff --git a/voltage-measurement-error/Pictures/Table 1. C-ADC DC Specifications.png b/voltage-measurement-error/Pictures/Table 1. C-ADC DC Specifications.png new file mode 100644 index 0000000..0d8ab25 Binary files /dev/null and b/voltage-measurement-error/Pictures/Table 1. C-ADC DC Specifications.png differ diff --git a/voltage-measurement-error/Pictures/Table 2. S-ADC DC Specifications.png b/voltage-measurement-error/Pictures/Table 2. S-ADC DC Specifications.png new file mode 100644 index 0000000..347fb57 Binary files /dev/null and b/voltage-measurement-error/Pictures/Table 2. S-ADC DC Specifications.png differ diff --git a/voltage-measurement-error/bilder/Fasttube-Logo.png b/voltage-measurement-error/bilder/Fasttube-Logo.png deleted file mode 100644 index b958efb..0000000 Binary files a/voltage-measurement-error/bilder/Fasttube-Logo.png and /dev/null differ diff --git a/voltage-measurement-error/bilder/adbms.png b/voltage-measurement-error/bilder/adbms.png deleted file mode 100644 index ab59f6b..0000000 Binary files a/voltage-measurement-error/bilder/adbms.png and /dev/null differ diff --git a/voltage-measurement-error/voltage-measurement-error.pdf b/voltage-measurement-error/voltage-measurement-error.pdf new file mode 100644 index 0000000..4292b4d Binary files /dev/null and b/voltage-measurement-error/voltage-measurement-error.pdf differ diff --git a/voltage-measurement-error/voltage-measurement-error.tex b/voltage-measurement-error/voltage-measurement-error.tex new file mode 100644 index 0000000..8281338 --- /dev/null +++ b/voltage-measurement-error/voltage-measurement-error.tex @@ -0,0 +1,60 @@ +\documentclass[paper=A4]{article} +\usepackage[utf8]{inputenc} + +\usepackage[a4paper, left=2cm, right=2cm, top=2cm, bottom=2cm]{geometry} + +\usepackage{siunitx} +\sisetup{ + group-separator = {.}, + input-decimal-markers={.}, + output-decimal-marker = {.}, + group-minimum-digits=9} +\usepackage{graphicx} +\usepackage{fancyhdr} +\usepackage{lastpage} +\usepackage{subfigure} +\usepackage{float} +\usepackage{wrapfig} +\usepackage{multicol} +\usepackage{amsmath, amssymb} + +\hyphenpenalty=10000 %to stop cutting words in a paragraph + +\pagestyle{fancy} +\fancyhf{} + +\rhead{\includegraphics*[scale=0.013]{./Pictures/FaSTTUBe_Logo_ohneAuto.png}} +\rfoot{Page \thepage \hspace{1pt} of \pageref{LastPage}} +\lhead{Car 313, 06.03, Rev. 1} +\chead{\large Voltage Measurement Error Calculation} + +\begin{document} + +We use the C-ADC of the ADBMS6830B to measure the cell voltages of the battery. +The maximum lifetime error for voltage measurement is $\pm \SI{2}{\milli\volt}$, since the maximum voltage of the cell is $\SI{4.2}{\volt}$. (Fig. \ref{fig:C-ADC}) \cite{datasheet} + +\begin{figure}[H] + \centering + \includegraphics[width=\textwidth]{./Pictures/Table 1. C-ADC DC Specifications.png} + \caption{Table 1. C-ADC DC Specifications} + \label{fig:C-ADC} +\end{figure} + +\begin{figure}[H] + \centering + \includegraphics[width=\textwidth]{./Pictures/Table 2. S-ADC DC Specifications.png} + \caption{Table 2. S-ADC DC Specifications} + \label{fig:S-ADC} +\end{figure} + +\bibliographystyle{plain} +%\nocite{*} + +\renewcommand\refname{Reference} +\begin{thebibliography}{00} + + \bibitem{datasheet} \textit{Data Sheet ADBMS6830B Rev.0 page 5}. analog.com, 01.2024. + +\end{thebibliography} + +\end{document}