diff --git a/temperature-measurement-error/AMS_T_error.pdf b/temperature-measurement-error/AMS_T_error.pdf deleted file mode 100644 index 27902b3..0000000 Binary files a/temperature-measurement-error/AMS_T_error.pdf and /dev/null differ diff --git a/temperature-measurement-error/AMS_temperature_error.pdf b/temperature-measurement-error/AMS_temperature_error.pdf new file mode 100644 index 0000000..c516455 Binary files /dev/null and b/temperature-measurement-error/AMS_temperature_error.pdf differ diff --git a/temperature-measurement-error/AMS_T_error.tex b/temperature-measurement-error/AMS_temperature_error.tex similarity index 91% rename from temperature-measurement-error/AMS_T_error.tex rename to temperature-measurement-error/AMS_temperature_error.tex index 08db5dc..82230e8 100644 --- a/temperature-measurement-error/AMS_T_error.tex +++ b/temperature-measurement-error/AMS_temperature_error.tex @@ -23,15 +23,15 @@ \pagestyle{fancy} \fancyhf{} -\rhead{\includegraphics*[scale=0.015]{./bilder/FaSTTUBe_Logo_ohneAuto.png}} +\rhead{\includegraphics*[scale=0.013]{./Pictures/FaSTTUBe_Logo_ohneAuto.png}} \rfoot{Page \thepage \hspace{1pt} of \pageref{LastPage}} -\lhead{Car 313, 06.03.2025, Rev. 1} +\lhead{Car 313, 06.03, Rev. 1} \chead{\large Temperature Measurement Error Calculation} \begin{document} \begin{wrapfigure}{l}{0.4\textwidth} - \includegraphics[width=1\linewidth]{./bilder/NTC-schematic.png} + \includegraphics[width=1\linewidth]{./Pictures/NTC-schematic.png} \caption{NTC Voltage Divider and Filter} \label{fig:NTC-schematic} \end{wrapfigure} @@ -55,14 +55,14 @@ The maximum possible voltage measurement can then be calculated as such: \begin{align} V_{worstcase} &= V_{REF2} \cdot \frac{R_{NTC}}{R_{NTC}+R_1} + V_{err} \\ &= \SI{3.006}\volt \cdot \frac{\SI{3086.8}{\ohm}}{\SI{3086.8}{\ohm}+\SI{9990}{\ohm}} + \SI{0.0028}{\volt} \\ - &\approx 0.7124\si\volt + &\approx \SI{0.7124}{\volt} \end{align} To find the largest possible error, the lowest possible matching temperature should be calculated, which theoretically can produce the same voltage output. The calculation is as follows: \begin{align} V_{worstcase} &= V_{REF2} \cdot \frac{R_{NTC}}{R_{NTC}+R_1} + V_{err} \\ - \SI{0.7124}{\ohm} &= \SI{2.994}{\volt} \cdot \frac{R_{NTC}}{R_{NTC}+\SI{10010}{\ohm}} - \SI{0.0028}{\volt} \\ + \SI{0.7124}{\volt} &= \SI{2.994}{\volt} \cdot \frac{R_{NTC}}{R_{NTC}+\SI{10010}{\ohm}} - \SI{0.0028}{\volt} \\ R_{NTC} &\approx \SI{3141.6}{\ohm} \end{align} @@ -70,14 +70,14 @@ Since the LUT is used to match the voltage to the temperature, and the nominal r \begin{figure}[H] \centering - \includegraphics[width=\textwidth]{./bilder/v_ref2.png} + \includegraphics[width=\textwidth]{./Pictures/Table 5. Voltage Reference Specifications.png} \caption{Voltage Reference Specifications} \label{fig:vref2} \end{figure} \begin{figure}[H] \centering - \includegraphics[width=\textwidth]{./bilder/aux.png} + \includegraphics[width=\textwidth]{./Pictures/Table 3. Auxiliary (AUX) ADC DC Specifications.png} \caption{Auxiliary (AUX) ADC DC Specifications} \label{fig:aux} \end{figure} diff --git a/temperature-measurement-error/bilder/FaSTTUBe_Logo_ohneAuto.png b/temperature-measurement-error/Pictures/FaSTTUBe_Logo_ohneAuto.png similarity index 98% rename from temperature-measurement-error/bilder/FaSTTUBe_Logo_ohneAuto.png rename to temperature-measurement-error/Pictures/FaSTTUBe_Logo_ohneAuto.png index fe69116..e402449 100644 Binary files a/temperature-measurement-error/bilder/FaSTTUBe_Logo_ohneAuto.png and b/temperature-measurement-error/Pictures/FaSTTUBe_Logo_ohneAuto.png differ diff --git a/temperature-measurement-error/bilder/NTC-schematic.png b/temperature-measurement-error/Pictures/NTC-schematic.png similarity index 100% rename from temperature-measurement-error/bilder/NTC-schematic.png rename to temperature-measurement-error/Pictures/NTC-schematic.png diff --git a/temperature-measurement-error/Pictures/Table 3. Auxiliary (AUX) ADC DC Specifications.png b/temperature-measurement-error/Pictures/Table 3. Auxiliary (AUX) ADC DC Specifications.png new file mode 100644 index 0000000..1273b7c Binary files /dev/null and b/temperature-measurement-error/Pictures/Table 3. Auxiliary (AUX) ADC DC Specifications.png differ diff --git a/temperature-measurement-error/Pictures/Table 5. Voltage Reference Specifications.png b/temperature-measurement-error/Pictures/Table 5. Voltage Reference Specifications.png new file mode 100644 index 0000000..ef3bff4 Binary files /dev/null and b/temperature-measurement-error/Pictures/Table 5. Voltage Reference Specifications.png differ diff --git a/temperature-measurement-error/bilder/Fasttube-Logo.png b/temperature-measurement-error/bilder/Fasttube-Logo.png deleted file mode 100644 index b958efb..0000000 Binary files a/temperature-measurement-error/bilder/Fasttube-Logo.png and /dev/null differ diff --git a/temperature-measurement-error/bilder/aux.png b/temperature-measurement-error/bilder/aux.png deleted file mode 100644 index 8bf9a70..0000000 Binary files a/temperature-measurement-error/bilder/aux.png and /dev/null differ diff --git a/temperature-measurement-error/bilder/v_ref2.png b/temperature-measurement-error/bilder/v_ref2.png deleted file mode 100644 index e597f93..0000000 Binary files a/temperature-measurement-error/bilder/v_ref2.png and /dev/null differ