[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 4669 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 4670 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 4670 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 4671 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4672 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4673 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 4673 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 4674 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4675 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4676 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4676 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4677 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5D 09 61 09 0F 09
|
|
[NOISY] 4678 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1E 09 FF FF FF FF
|
|
[NOISY] 4679 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 4679 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4680 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 4784 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 4784 R | 00 27
|
|
[NOISY] 4785 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4785 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 4797 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 4798 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 4798 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 4799 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4800 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4801 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 4801 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 4802 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4803 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4804 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4804 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4805 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5D 09 61 09 0F 09
|
|
[NOISY] 4806 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 4807 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3D
|
|
[NOISY] 4807 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4808 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 4912 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 4912 R | 00 27
|
|
[NOISY] 4913 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4913 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 4925 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 4926 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 4926 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 4927 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4928 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4929 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 4929 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 4930 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4931 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4932 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4932 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 4933 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 61 09 0E 09
|
|
[NOISY] 4934 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 4935 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 4935 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 4936 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Lo
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 0 voltage issues - OV: 0x00000001, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[INFO] Module 1 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 1859 C13: 1860 C14: 1847 C15: 1849
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 1 voltage issues - OV: 0x00000000, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 5044 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5044 R | 00 27
|
|
[NOISY] 5045 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5045 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 5057 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 5058 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 5058 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 5059 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5060 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5061 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5061 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 5062 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5063 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5064 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5064 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5065 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5D 09 61 09 0F 09
|
|
[NOISY] 5066 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 5067 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3D
|
|
[NOISY] 5067 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5068 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 5172 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5172 R | 00 27
|
|
[NOISY] 5173 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5173 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 5185 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 5186 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 5186 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 5187 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5188 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5189 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5189 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 5190 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5191 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5192 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5192 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5193 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 61 09 0E 09
|
|
[NOISY] 5194 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 5195 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 5195 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5196 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 5300 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5300 R | 00 27
|
|
[NOISY] 5301 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5301 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 5313 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 5314 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 5314 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 5315 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5316 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5317 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5317 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 5318 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5319 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5320 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5320 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5321 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 61 09 0E 09
|
|
[NOISY] 5322 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 5323 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 5323 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5324 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 5428 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5428 R | 00 27
|
|
[NOISY] 5429 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5429 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 5441 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 5442 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 5442 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 5443 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5444 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5445 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5445 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 5446 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5447 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5448 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5448 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5449 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 61 09 0E 09
|
|
[NOISY] 5450 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 5451 R | 00 33 0: 55 95 56 55 FF 3F 1: 55 55 55 55 FF 3C
|
|
[NOISY] 5451 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5452 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[INFO] Module 0 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 0 C13: 0 C14: 0 C15: 0
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 0 voltage issues - OV: 0x00000001, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[INFO] Module 1 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 1859 C13: 1860 C14: 1847 C15: 1849
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 1 voltage issues - OV: 0x00000000, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 5560 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5560 R | 00 27
|
|
[NOISY] 5561 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5561 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 5573 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 5574 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 5574 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 5575 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5576 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5577 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5577 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 5578 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5579 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5580 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5580 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5581 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0E 09
|
|
[NOISY] 5582 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 5583 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 5583 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5584 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 5688 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5688 R | 00 27
|
|
[NOISY] 5689 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5689 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 5701 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 5702 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 5702 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 5703 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5704 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5705 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5705 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 5706 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5707 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5708 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5708 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5709 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0E 09
|
|
[NOISY] 5710 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1C 09 FF FF FF FF
|
|
[NOISY] 5711 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 5711 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5712 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 5816 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5816 R | 00 27
|
|
[NOISY] 5817 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5817 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 5829 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 5830 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 5830 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 5831 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5832 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5833 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5833 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 5834 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5835 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5836 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5836 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5837 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 61 09 0E 09
|
|
[NOISY] 5838 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 5839 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 5839 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5840 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 5944 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5944 R | 00 27
|
|
[NOISY] 5945 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5945 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 5957 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 5958 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 5958 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 5959 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5960 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 5961 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 5961 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 5962 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5963 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5964 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5964 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 5965 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0D 09
|
|
[NOISY] 5966 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 0 voltage issues - OV: 0x00000001, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[INFO] Module 1 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 1859 C13: 1860 C14: 1847 C15: 1849
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 1 voltage issues - OV: 0x00000000, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 6076 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6076 R | 00 27
|
|
[NOISY] 6077 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6077 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 6089 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 6090 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 6090 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 6091 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6092 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6093 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6093 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 6094 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6095 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6096 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6096 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6097 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0E 09
|
|
[NOISY] 6098 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 6099 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3D
|
|
[NOISY] 6099 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6100 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 6204 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6204 R | 00 27
|
|
[NOISY] 6205 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6205 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 6217 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 6218 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 6218 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 6219 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6220 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6221 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6221 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 6222 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6223 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6224 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6224 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6225 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5B 09 60 09 0D 09
|
|
[NOISY] 6226 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1C 09 FF FF FF FF
|
|
[NOISY] 6227 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 6227 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6228 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 6332 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6332 R | 00 27
|
|
[NOISY] 6333 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6333 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 6345 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 6346 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 6346 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 6347 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6348 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6349 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6349 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 6350 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6351 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6352 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6352 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6353 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0E 09
|
|
[NOISY] 6354 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 6355 R | 00 33 0: 55 95 56 55 FF 3F 1: 55 55 55 55 FF 3D
|
|
[NOISY] 6355 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6356 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 6460 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6460 R | 00 27
|
|
[NOISY] 6461 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6461 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 6473 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 6474 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 6474 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 6475 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6476 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6477 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6477 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 6478 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6479 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6480 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6480 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6481 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0D 09
|
|
[NOISY] 6482 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 6483 R | 00 33 0: 55 95 56 55 FF 3F 1: 55 55 55 55 FF 3D
|
|
[NOISY] 6483 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6484 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[INFO] Module 0 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 0 C13: 0 C14: 0 C15: 0
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal tempissues - OV: 0x00000001, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[INFO] Module 1 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 1859 C13: 1860 C14: 1847 C15: 1849
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 1 voltage issues - OV: 0x00000000, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 6592 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6592 R | 00 27
|
|
[NOISY] 6593 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6593 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 6605 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 6606 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 6606 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 6607 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6608 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6609 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6609 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 6610 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6611 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6612 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6612 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6613 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0E 09
|
|
[NOISY] 6614 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1D 09 FF FF FF FF
|
|
[NOISY] 6615 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3D
|
|
[NOISY] 6615 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6616 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 6720 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6720 R | 00 27
|
|
[NOISY] 6721 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6721 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 6733 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 6734 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 6734 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 6735 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6736 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6737 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6737 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 6738 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6739 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6740 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6740 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6741 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5B 09 60 09 0D 09
|
|
[NOISY] 6742 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1C 09 FF FF FF FF
|
|
[NOISY] 6743 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 6743 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6744 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 6848 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6848 R | 00 27
|
|
[NOISY] 6849 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6849 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 6861 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 6862 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 6862 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 6863 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6864 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6865 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6865 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 6866 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6867 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6868 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6868 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6869 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5B 09 60 09 0D 09
|
|
[NOISY] 6870 R | 00 0B 0: F4 D8 FF FF FF F[31m[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 6976 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6976 R | 00 27
|
|
[NOISY] 6977 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6977 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 6989 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 6990 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 6990 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 6991 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6992 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 6993 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 6993 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 6994 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6995 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6996 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6996 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 6997 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0D 09
|
|
[NOISY] 6998 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1C 09 FF FF FF FF
|
|
[NOISY] 6999 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3D
|
|
[NOISY] 6999 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7000 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[INFO] Module 0 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 0 C13: 0 C14: 0 C15: 0
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 0 voltage issues - OV: 0x00000001, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[INFO] Module 1 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 1859 C13: 1860 C14: 1847 C15: 1849
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2:
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 7108 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 7108 R | 00 27
|
|
[NOISY] 7109 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7109 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 7121 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 7122 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 7122 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 7123 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7124 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7125 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 7125 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 7126 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7127 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7128 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7128 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7129 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5C 09 60 09 0D 09
|
|
[NOISY] 7130 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1C 09 FF FF FF FF
|
|
[NOISY] 7131 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3D
|
|
[NOISY] 7131 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7132 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 7236 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 7236 R | 00 27
|
|
[NOISY] 7237 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7237 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 7249 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 7250 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 7250 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 7251 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7252 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7253 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 7253 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 7254 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7255 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7256 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7256 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7257 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5B 09 60 09 0D 09
|
|
[NOISY] 7258 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1C 09 FF FF FF FF
|
|
[NOISY] 7259 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3D
|
|
[NOISY] 7259 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7260 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 7364 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 7364 R | 00 27
|
|
[NOISY] 7365 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7365 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 7377 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 7378 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 7378 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 7379 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7380 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7381 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 7381 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 7382 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7383 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7384 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7384 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7385 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5B 09 60 09 0D 09
|
|
[NOISY] 7386 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1C 09 FF FF FF FF
|
|
[NOISY] 7387 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3C
|
|
[NOISY] 7387 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7388 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[ERROR] Too many errors, restarting BMS...
|
|
[INFO] ADBMS6830B HAL - configured for 2 controllers and 16 cells per controller...
|
|
[NOISY] 7492 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 7492 R | 00 27
|
|
[NOISY] 7493 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7493 R | 00 2C 0: AD 06 6F 25 4A 67 1: B2 86 07 E4 69 DB
|
|
[INFO] BMS reset complete
|
|
[INFO] Found IDs: 0x0256f06ad 0xffffffffe40786b2
|
|
[NOISY] 7505 R | 00 02 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[INFO] Configuring OV/UV thresholds to 4200 mV (1125 internal) / 3000 mV (625 internal)
|
|
[NOISY] 7506 R | 00 26 0: 00 F8 7F 00 00 00 1: 00 F8 7F 00 00 00
|
|
[NOISY] 7506 W | 00 24 0: 71 52 46 00 00 00 1: 71 52 46 00 00 00
|
|
[NOISY] 7507 W | 07 17 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7508 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7509 R | 00 02 0: 01 00 00 FF 03 10 1: 01 00 00 FF 03 10
|
|
[NOISY] 7509 R | 00 32 0: 00 00 00 00 00 00 1: 00 00 00 00 00 00
|
|
[NOISY] 7510 R | 00 04 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7511 R | 00 06 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7512 R | 00 08 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7512 R | 00 0A 0: 00 80 00 80 00 80 1: 00 80 00 80 00 80
|
|
[NOISY] 7513 R | 00 09 0: F5 D8 F5 D8 F5 D8 1: 5B 09 60 09 0D 09
|
|
[NOISY] 7514 R | 00 0B 0: F4 D8 FF FF FF FF 1: 1C 09 FF FF FF FF
|
|
[NOISY] 7515 R | 00 33 0: 55 95 56 55 FF 3E 1: 55 55 55 55 FF 3D
|
|
[NOISY] 7515 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[NOISY] 7516 W | 07 15 0: FF FF FF FF FF FF 1: FF FF FF FF FF FF
|
|
[ERROR] AMS_Idle_Loop returned 3 (ADBMS_OVERVOLT) on BMS 0
|
|
[INFO] Module 0 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 0 C13: 0 C14: 0 C15: 0
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 0 voltage issues - OV: 0x00000001, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[INFO] Module 1 status:
|
|
[INFO] Cell voltages (mV):
|
|
[INFO] C0: -3415 C1: -3415 C2: -3415 C3: -3415
|
|
[INFO] C4: -3415 C5: -3415 C6: -3415 C7: -3415
|
|
[INFO] C8: -3415 C9: -3415 C10: -3415 C11: -3415
|
|
[INFO] C12: 1859 C13: 1860 C14: 1847 C15: 1849
|
|
[INFO] GPIO values:
|
|
[INFO] G0: 0 G1: 0 G2: 0 G3: 0 G4: 0
|
|
[INFO] G5: 0 G6: 0 G7: 0 G8: 0 G9: 0
|
|
[INFO] Internal temp: 0, VAnalog: 0, VDigital: 0, VRef: 0
|
|
[INFO] Status flags: [none]
|
|
[INFO] Conversion counter: 0
|
|
[WARN] Module 1 voltage issues - OV: 0x00000000, UV: 0x00000001
|
|
[INFO] ---------------
|
|
[ERROR] Too many errors, restarting BMS... |