add isolation test data from pickering

This commit is contained in:
LeneMarquardt 2025-02-22 17:09:32 +01:00
parent 1b5573637b
commit 49cf4fa011
2 changed files with 8 additions and 7 deletions

View File

@ -1517,7 +1517,7 @@
)
(uuid "b075c53d-92c9-456d-abf7-eed816b092d6")
)
(text "opto diode current:\n@ maximum TS Voltage 403V = 4,27 mA\n@ minimum TS Voltage 240V = 2,17 mA"
(text "opto diode current:\n@ maximum TS Voltage 403V = 4,27 mA\n@ minimum TS Voltage 240V = 2,55 mA"
(exclude_from_sim no)
(at 156.972 56.642 0)
(effects

View File

@ -2708,9 +2708,9 @@
)
(uuid "4bf667c7-6d83-4e70-8138-986a1f12963f")
)
(text "TS-LV isolation via pin distance in relay (5.1mm between pins)"
(text "TS-LV isolation via relay pn distance (10.16mm)"
(exclude_from_sim no)
(at 190.754 52.07 0)
(at 189.484 52.832 0)
(effects
(font
(size 1.27 1.27)
@ -2720,7 +2720,7 @@
)
(text "TS"
(exclude_from_sim no)
(at 203.708 132.969 0)
(at 203.708 133.35 0)
(effects
(font
(size 10 10)
@ -2731,13 +2731,14 @@
)
(uuid "d0980a2d-0eca-4408-8d7c-96c1603edca8")
)
(text "add isolation rating here :)"
(text "\"Regarding your questions about our testing process, we \nperform high voltage tests at 5.5 kV DC/AC Peak \n(switch-to-switch and switch-to-coil) for the \n104-1-A-24/5D relay.\"\n\n- Ahmet Turan (Assistant Reed Relay Product Manager)"
(exclude_from_sim no)
(at 173.228 56.896 0)
(at 165.608 62.23 0)
(effects
(font
(size 1.27 1.27)
)
(justify left)
)
(uuid "d9364e3a-baff-41e1-a2f8-eca54a1d6f77")
)
@ -2987,7 +2988,7 @@
)
)
)
(property "Value" "104-2-A-24/5D "
(property "Value" "104-1-A-24/5D "
(at 139.065 63.5 90)
(effects
(font